Lawn
Sprinkler
Pump
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop-
erty damage! Retain instructions for future reference.
© 1998 Wayne Home Equipment
Description
This pump is a high capacity, self-prim-
ing centrifugal pump suitable for lawn
sprinkling or other applications where
large quantities of water are required.
Flammable liquids such as gasoline,
chemicals or corrosive liquids should
never be used with this pump.
Safety Guidelines
This manual contains information that
is very important to know and under-
stand. This information is provided for
SAFETY and to PREVENT EQUIPMENT
PROBLEMS. To help recognize this
information, observe the following
symbols.
Danger indicates
an imminently haz-
ardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
a potentially haz-
ardous situation which, if not avoided,
could result in death or serious injury.
Caution indicates a
potentially haz-
ardous situation which, if not avoided,
may result in minor or moderate injury.
Notice indicates
important informa-
tion, that if not followed, may cause
damage to equipment.
General Safety Information
1. Read these rules and
instructions carefully.
Failure to follow these
instuctions could
cause serious bodily
injury and/or property damage.
!
NOTICE
Operating Instructions and Parts Manual WLS Series
This pump is non-
submersible.
Pump only clear water. Do
not pump flammable or
explosive fluids such as
gasoline, fuel oil,
kerosene, etc. Do not use in a flamma-
ble and/or explosive atmosphere.
Personal injury and/or property dam-
age could result.
This pump is not
designed to handle
salt water, brine, laundry discharge or
any other application which may con-
tain caustic chemicals and/or foreign
materials. Pump damage could occur if
used in these applications and will
void warranty.
All wiring must be per-
formed by a qualified
electrician. The pump
must be installed in com-
pliance with all local and national
codes.
2. Connect this product to a grounded
circuit equipped with a ground
fault interruptor device.
3. Before installing this product, have
the electrical circuit checked by an
electrican to ensure proper ground-
ing.
4. BE CERTAIN the pump
power source is dis-
connected before
installing or servicing
pump.
5. Check motor voltage setting on
motor endplate and make sure the
line voltage of the electrical current
supply is correct.
6. Be sure the water source and piping
is clear of sand, dirt and scale.
!
NOTICE
320200-001 6/98
Debris will clog pump and void war-
ranty.
7. Failure to protect pump and piping
from freezing could cause severe
damage and will void the warranty.
8. Do not run pump dry. Follow prim-
ing instructions.
Installation
Protect pump from the elements by
installing in a basement, garage, tool
shed or pump house. Install the pump so
the centerline of the pump is as close as
possible to the water level. Keep installa-
tion area clear to provide access for ser-
vice and maintenance. Protect the pump
against flooding and excess moisture.
Make sure the pump has adequate ven-
tilation. The surrounding temperature
should not exceed 100
o
F (38
o
C) or nui-
sance tripping of the motor may occur.
PUMP PIPING INSTALLATION
Use new pipe for best results.
Galvanized or plastic pipe can be used.
When using galvanized pipe, provide
independent supports for both suction
and discharge piping near the pump to
avoid strain on the pump. Minimize use
of elbows and fittings to reduce friction
loss. Refer to the friction loss chart for
specific information.
Increase diameter of suction or dis-
charge piping if length is over 50 feet.
SUCTION PIPING
Install foot valve
or strainer screen
over intake of suction piping.
Never use pipe smaller than 2” in
diameter for suction piping. The suc-
tion pipe must be kept free of air leaks.
MANUAL
Vue de la page 0
1 2 3 4 5

Résumé du contenu

Page 1 - Sprinkler

LawnSprinklerPumpPlease read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product descr

Page 2 - Lawn Sprinkler Pump

2Operating Instructions and Parts ManualInstallation (Continued)For horizontal runs, lay pipe from thewater source so the upward slope is atleast 1/2”

Page 3 - WLS Series

OperationNever run the pump dry. Runningpump without water may cause sealdamage. Fill the pump with waterbefore starting.PRIMING THE PUMPAfter pump in

Page 4

Operating Instructions and Parts ManualLawn Sprinkler Pump4Maintenance (Continued)DRAINING FOR WINTERAlways protect pump and pipingagainst freezing te

Page 5

1234568791011Operating Instructions and Parts Manual1 Motor 32031-001 32015-001 32020-001 32021-001 12 3/8”-16 x 1” Hex cap screw 16334 16334 16334 16