Installation (Continued)
3. Install a valve and isolator hose between
the system and the house plumbing to
aid in pump removal for servicing and
for reducing noise transmitted to the
house through the piping.
4. Provide a hose bib (faucet) at the
lowest point in the system to drain
for service or storage.
CONVERTING THE DEEP WELL PUMP TO
SHALLOW WELL OPERATION (FIGURE 8)
For shallow wells (25 feet or less), a
bolt-on shallow well jet is available
as an accessory for deep well pumps.
The jet attaches to the front of the
pump with the two bolts provided and
converts the deep well pump into a
shallow well pump. The shallow well
jet has a 1 in. NPT inlet and a 1/8 in.
NPT opening for an air volume control.
For optimum performance, an inline
check valve on the inlet side of the
shallow well jet is recommended.
Electrical
Risk of electrical
shock. This pump is
designed for indoor installation only.
Select the proper size wire and
fuse (Chart 2). Time delay fuses are
recommended over standard fuses
for motor circuit protection. All pump
motors have built-in automatic overload
protection that will prevent damage to
the motor due to overheating.
Do NOT connect to
electric power supply
until unit is permanently grounded.
Connect ground wire to approved ground
then connect terminal provided.
A metal underground water pipe or
well casing at least 10 feet long makes
the best ground electrode. If plastic
pipe or insulated fittings are used, run
a wire directly to the metal well casing
or use a ground electrode furnished by
the power company.
There is only one proper ground
terminal on the unit. The terminal is
located under the pressure switch cover,
is painted green and is identified as
GRD. The ground connection must be
made at this terminal (Figure 9).
The ground conductor must not be
smaller than the circuit conductors
supplying the motor.
The voltage of power supply must match
the voltage of the pump. The unit has
dual voltage motors preset at the factory
to 115 volts. The motors can be converted
to 230 volts by turning the voltage
selector to the desired voltage (see Figure
10, on page 5). Disconnect power, use
needle nose pliers to pull the selector out
approximately 1/4 in., rotate, and then
reinsert in correct position.
Disconnect power
and release ALL
pressure from the system before
attempting to install, service, relocate
or perform any maintenance.
Operation
PRIMING THE SHALLOW WELL PUMP
To prevent damage
to the pump, do NOT
start motor until pump has been filled
with water.
NOTE: When the deep well pump is used
with the bolt-on shallow well jet, be sure
the control valve slot (Figure 11, on page
6) is in the vertical (open) position at all
times.
1. Remove prime plug.
2. Fill pump and piping completely full
of water.
3. Replace the prime plug.
4. Open a faucet to vent the system.
5. Start the motor. Water will pump in a
few minutes. If pump fails to prime in
5 minutes, stop motor and refill pump
with water. Priming time is proportional
to the amount of air in inlet pipe. Do
not allow pump to get hot.
6. Let the system operate for several
minutes to flush all pipes.
CWS Series
Figure 7 - Pre-charged Storage Tank
OUTLET
PRIME
PLUG
TO DRIVE
TO JET
28-30 PSI PRECHARGE
1/2, 1/3 & 1 HP
TO
SUCTION
PRESSURE
SWITCH
Figure 8 - Shallow Well Jet
TO AIR VOLUME
CONTROL
JET
CHART 2 - RECOMMENDED FUSE AND WIRING DATA - 60 HZ MOTORS
HP Volt
Dual
Element
Fuse
250V
Distance in Feet
From Meter to Motor
0 51 101 201
to to to to
50 100 200 300
Wire Size
1/2
115 15 14 12 10 8
230 10 14 14 14 14
3/4
115 15 14 12 8 6
230 10 14 14 14 12
1
115 20 14 12 8 6
230 10 14 14 14 12
L2
3
L1
1
Figure 9 - Electrical Connections
MOTOR
LINE
GROUND
SCREW
Figure 10 - Voltage Selector
230 V
115 V
Vue de la page 4